This part of lEC 60974 is applicable to equipment for arc welding and allied processes,including power sources and ancillary equipment,for example wire feeders,liquid coolingsystems, arc striking and stabilizing devices and chargers for battery powered equipment.
NOTE 1 Allied processes are, for example,plasma cutting and arc stud welding.
NOTE 2 This document does not specify basic safety requirements for arc welding equipment such as protectionagainst electric shock,unsafe operation, insulation coordination and related dielectric tests.
Arc welding equipment containing a radio receiver or transmitter is within the scope of thisdocument.
The radiated emission requirements in this document are not intended to be applicable to theintentional transmissions from a radio transmitter as defined by the lTU nor to any spuriousemissions related to these intentional transmitters.
This document specifies
a) applicable standards and test methods for radio-frequency (RF) emissions;
b) applicable standards and test methods for harmonic current emission, voltage fluctuations and flicker;
c)immunity requirements and test methods for continuous and transient,conducted and radiated disturbances including electrostatic discharges;
d) additional requirements for equipment powered by internal or external batteries (Annex D);
e) additional requirements for equipment containing radio frequency transmitters/receivers (Annex E).
Arc welding equipment type tested in accordance with,and which has met the requirementsset in, this document is considered to be in compliance for all applications.
2Normative references
The following documents are referred to in the text in such a way that some or all of theircontent constitutes requirements of this document. For dated references,only the editioncited applies. For undated references, the latest edition of the referenced document(includingany amendments) applies.
IEC 60974-1:2017,Arc welding equipment – Part 1: Welding power sourcesIEC 60974-1:2017IAMD1:2019
IEC 60974-6:2015,Arc welding equipment – Part 6: Limited duty equipment
IEC 61000-3-2:2018,Electromagnetic compatibility (EMC) – Part 3-2: Limits – Limits forharmonic current emissions (equipment input current s 16 A per phase)
IEC 61000-3-3:2013,Electromagnetic compatibility (EMC) – Part 3-3: Limits – Limitation ofvoltage changes,voltage fluctuations and flicker in public low-voltage supply systems,forequipment with rated current s16 A per phase and not subject to conditional connection
lEc61000-3-3:2013/AMD1:2017
IEC 61000-3-11:2017,Electromagnetic compatibility (EMC) – Part 3-11: Limits – Limitation ofvoltage changes,voltage fluctuations and flicker in public low-voltage supply systems -Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12:2011,Electromagnetic compatibility (EMC) – Part 3-12:Limits for harmoniccurrents produced by equipment connected to public low-voltage systems with input current >16 A and s 75 A per phase
IEC 61000-4-2:2008, Electromagnetic compatibility(EMC) – Part 4-2: Testing andmeasurement techniques – Electrostatic discharge immunity test
IEC 61000-4-3:2006, Electromagnetic compatibility(EMC) – Part 4-3: Testing andmeasurement techniques – Radiated,radio-frequency,electromagnetic field immunity testIEC61000-4-3:2006/AMD1:2007
IEC 61000-4-3:2006IAMD2:2010
IEC 61000-4-4:2012,Electromagnetic compatibility(EMC) – Part 4-4: Testing andmeasurement techniques – Electrical fast transient/burst immunity test
IEC 61000-4-5:2014,Electromagnetic compatibility(EMC) – Part 4-5: Testing andmeasurement techniques – surge immunity test
IEC61000-4-5:2014/AMD1:2017
IEC 61000-4-6:2013, Electromagnetic compatibility(EMC) – Part 4-6: Testing andmeasurement techniques – lmmunity to conducted disturbances,induced by radio-frequencyfields
IEC 61000-4-11:2004, Electromagnetic compatibility(EMC) – Part 4-11: Testing andmeasurement techniques – Voltage dips,short interruptions and voltage variations immunitytests
lEC 61000-4-11:2004/AMD1:2017
3 Terms and definitions
For the purposes of this document, terms and definitions in IEC 60974-1 as well as the following apply.
ISO and IEC maintain terminological databases for use in standardization at the following addresses:
• IEC Electropedia: available at http://www.electropedia.org/
• ISO Online browsing platform: available at http://www.iso.org/obp
3.1 click
disturbance which exceeds the limit of continuous disturbance no longer than 200 ms and which is separated from a subsequent disturbance by at least 200 ms
Note 1 to entry: Both intervals are related to the level of the limit of continuous disturbance.
Note 2 to entry: A click may contain a number of impulses, in which case the relevant time is that from the beginning of the first to the end of the last impulse.IEC 60974-10 pdf download.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.
IEC 61300-2-40-2000 pdf free download – Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors IEC Standards

IEC 61300-2-40-2000 pdf free download – Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors

IEC 61300-2-40-2000 pdf free download - Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors. 1.1Scope and...
Download Now

LEAVE A REPLY

Anonymous netizen Fill in information