4General requirements
This standard prescribes the outline drawing views and the dimensions and descriptionsrequired for documenting a generic CRT design.The recommendations for each drawing arespecified in 5.1,5.2,5.3 and specimen drawings are shown in figure 1 through figure 18.
lf the phosphor screen extent is hidden by the band,the degree of vignetting should beindicated on one of the views.
4.1 Required views
In general, the views required to describe a rectangular CRT shall be the front, top, side anddiagonal. When the implosion protection and mounting system is integral to the tube,asecond front view and the mounting lug outline drawing may be included.
The components of the CRT (panel,funnel,base,reference line gauge, beam clearancegauge and ancillary equipment) are part of the outline drawing information.
Monochrome and projection CRTs may not require all of the entries. lf the dimensionsmentioned in the tabular layout below the specimen outline drawings are applicable to thetube to be described, they shall be given on the outline sheet.
lf the CRT has appendages or features not described in this standard, additional views shallbe included to fully describe them.
4.2General rules and guidelines for the outline drawings
The specific guidelines for each drawing have been chosen based on balancing the amount ofdetail and quantity of dimensions on each drawing. If future designs require more or lessdetail on certain views, it is appropriate to relocate dimensional information to other views solong as the information is retained in an unambiguous manner.
The drawing shall show all dimensions necessary to assure clearances and mating withauxiliary accessories.
Drawings need not be drawn to scale,but they shall be roughly in proportion and,wherenecessary for clarity,an enlarged detail drawing shall be used.
Angles shall be indicated as follows:
a) by quoting the value in degrees and minutes and seconds or in decimal notation. Wherethis is not practical, the value may be quoted in fractions of degrees;
b) where it is self-evident that a number of angles are of equal value, the value of only one of those angles shall be quoted.
5 Specific requirements
5.1Specific requirements of CRT outline drawings
The following views and related dimensions shall be included where appropriate. Where it ispossible to combine this data into fewer views, this is permissible. Where additional types ofdimensions are deemed useful, they may be included.
Each of the following subclauses identifies the suggested data for a drawing. Data can beshown on other drawings if it is more convenient.
5.1 .1 Front view of the CRT
The front view shall provide values for the following list of dimensions, as shown in figure 1 :
• dimension of the CRT including mounting system;
• clearance for the band junction when positioned on the minor or major axis;
• distances between the centres of the CRT mounting holes;
• design aspect ratio;
• dimensions of the minimum, nominal and maximum useful phosphor screen;
• curvature of the useful phosphor (if not straight);
• location of the “Z-point”;
• electron gun positions (designated R, G, B);
• clock position of the anode connector.
5.1 .2 Top view of the CRT
The top (or bottom) view shall show the anode connector and provide values for the following list of dimensions, as shown in figure 2:
• neck outside diameter;
• location for the convergence device;
• area for reliable contact to the outer conductive coating;
• major axis dimensions of the band;
• base and anode connector type designations.
5.1 .3 Side view of the CRT
The side view shall provide values for the following list of dimensions, as shown in figure 3:
• overall length of the CRT;
• reference line location;
• frit seal line location;
• anode contact location;
• description of the implosion system (i.e. tension band, shrink fit, etc.).IEC 60139 pdf download.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.
IEC 61300-2-40-2000 pdf free download – Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors IEC Standards

IEC 61300-2-40-2000 pdf free download – Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors

IEC 61300-2-40-2000 pdf free download - Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors. 1.1Scope and...
Download Now

LEAVE A REPLY

Anonymous netizen Fill in information