4 Requirements
4.1 Quality verification Fallopian rings are mass produced articles manufactured in very large quantities. Inevitably, there will be some variation between individual rings, and a small proportion of rings in each production run might not meet the requirements of this document. Further, the majority of the test methods described in this document are destructive. For these reasons, the only practicable method of assessing conformity with this document is by testing a representative sample from a lot or series of lots. Basic sampling plans are given in ISO 2859-1. Reference should be made to ISO/TR 8550 (all parts) for guidance on the use of acceptance sampling system, scheme or plan for the inspection of discrete items in lots. When on-going verification is required of the quality of fallopian rings, it is suggested that, instead of concentrating solely on evaluation of the final product, attention is also directed at the manufacturer’s quality system. It should be noted that ISO 13485 covers the provision of an integrated quality system for the manufacture of medical devices. Sampling plans shall be selected to provide an acceptable level of consumer protection. Suitable sampling plans are given in Annexes A and B.
a) Annex A describes sampling plans based on ISO 2859-1 and is most applicable to manufacturers or purchasers assessing the conformity of a continuing series of lots. The full level of consumer protection available depends upon the switch to tightened inspection if deterioration in quality is detected. The switching rules, described in ISO 2859-1:1999, Clause 9, cannot offer their full protection for the first two lots tested but become progressively more effective as the number of lots in a series increases. Use the sampling plans in Annex A when five or more lots are being tested.
b) Annex B describes sampling plans, based on ISO 2859-1, that are recommended for the assessment of isolated lots. The sampling plans in Annex B provide approximately the same level of consumer protection as those given in Annex A when used with the switching rules.
It is recommended that these sampling plans are used for the assessment of fewer than five lots, for example in cases of dispute, for referee purposes, for type testing, for qualification purposes or for short runs of continuing lots. It is necessary to know the lot size in order to derive the number of fallopian rings to be tested from ISO 2859-1. The lot size will vary between manufacturers and is regarded as part of the process and quality controls used by the manufacturer. If the lot size is not known or cannot be confirmed by the manufacturer, then a lot size of 10,000 fallopian rings shall be assumed for determining the sample sizes for testing.
4.2 Physical requirements
4.2.1 Dimensions Fallopian rings are tested for the inner diameter and outer diameter in accordance with Annex C and shall conform to the requirements given in Figure 1. Cut rings shall be free from fibrous protrusions at the outer and inner surface. Angle of cut shall be at 90° (≤5° angulations is allowed).
4.2.2 Tensile properties
Fallopian rings tested in accordance with Annex D for the tensile properties shall conform to the requirements stated below.
a) The force at break shall be ≥20,50 N.
b) Elongation at force at break shall be ≥560 %.
4.2.3 Loading force on ring applicator
Fallopian rings tested in accordance with Annex E for the force of loading on ring applicator shall conform to the requirement stated below.
The force required to load fallopian rings on the ring applicator shall be ≤35 N.
4.2.4 Elastic memory
Fallopian rings tested in accordance with Annex F for the elastic memory shall conform to the requirement stated below.
The recovery of the inner diameter shall be such that the increase in the inner diameter ≤25 % of the original diameter.
4.2.5 Repeat loading strength
Fallopian rings tested in accordance with Annex G for the repeat loading strength shall neither break nor develop any cracks when viewed using ×20 magnification.
4.2.6 Visible defects
Fallopian rings tested for the visible defects shall not have defects such as discolouration, any fibres or protrusions on the ring.
4.3 Packaging
4.3.1 Packing mode
One pair of fallopian rings shall be packaged in peel open pouch/blister pack with seal width ≥2 mm.BS ISO 19351 pdf download.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.
BS ISO 9349-2017 pdf free download BS Standards

BS ISO 9349-2017 pdf free download

BS ISO 9349-2017 pdf free download.Ductile iron pipes, fittings, accessories and their joints — Thermal preinsulated products 4 Technical requirements 4.1 General A preinsulated pipe (or fitting) is generally manufactured by injection moulding the polyurethane foam thermal...
Download Now
BS EN 2033-2017 pdf free download BS Standards

BS EN 2033-2017 pdf free download

BS EN 2033-2017 pdf free download.Aerospace series — Strips, cold rolled in steel, Thickness 0,1 mm ≤ a ≤ 2,5 mm — Dimensions This European Standard specifies the dimensions and tolerances of: Strips, cold rolled in steel...
Download Now
BS EN 2017-1989 pdf free download BS Standards

BS EN 2017-1989 pdf free download

BS EN 2017-1989 pdf free download.Specification for Bearings-airframe rolling double row self aligning ball bearings in corrosion resisting steel diameter series 2 — Dimensions and loads This standard specifies the characteristics, of double row self aligning ball...
Download Now

LEAVE A REPLY

Anonymous netizen Fill in information