This part of lEC 60317 specifies the requirements of solderable enamelled round copperwinding wire of class 130 with a sole coating based on polyurethane resin,which may bemodified provided it retains the chemical identity of the original resin and meets all specifiedwire requirements.
NOTEA modfied resin is a resin that has undergone a chemical change,or contains one or more additives toenhance certain performance or application characteristics.
The range of nominal conductor diameters covered by this standard is:-Grade 1:0,018 mm up to and including 2,000 mm;
-Grade 2: 0,020 mm up to and including 2,000 mm.
The nominal conductor diameters are specified in Clause 4 of IEC 60317-0-1:2013.
2Normative references
The following documents, in whole or in part, are normatively referenced in this document andare indispensable for its application.For dated references, only the edition cited applies.Forundated references,the latest edition of the referenced document (including anyamendments) applies.
IEC 60317-0-1:2013,Specifications for particular types of winding wires – Part 0-1:Generalrequirements – Enamelled round copper wire
3Terms, definitions, general notes and appearance
3.1 Terms and definitions
For the purposes of this document,the terms and definitions given in 3.1 of IEC 60317-0-1 :2013 apply.
3.2General notes3.2.1 Methods of test
Subclause 3.2 of IEC 60317-0-1:2013 applies. In case of inconsistencies betweenIEC60317-0-1 and this standard,IEC60317-4 shall prevail.
3.2.2Winding wire
Class 130 is a thermal class that requires a minimum temperature index of 130 and a heatshock temperature of at least 155°C.
The temperature in degrees Celsius corresponding to the temperature index is not necessarilythat at which it is recommended that the wire be operated and this will depend on manyfactors,including the type of equipment involved.
3.2.3 Appearance
Subclause 3.3 of IEC 6031 7-0-1 :201 3 applies.
4 Dimensions
Clause 4 of IEC 6031 7-0-1 :201 3 applies.
5 Electrical resistance
Clause 5 of IEC 6031 7-0-1 :201 3 applies.
6 Elongation
Clause 6 of IEC 6031 7-0-1 :201 3 applies.
7 Springiness
Clause 7 of IEC 6031 7-0-1 :201 3 applies.
8 Flexibility and adherence
Clause 8 of IEC 6031 7-0-1 :201 3 applies. The constant K used for the calculation of the number of revolutions for the peel test shall be 1 50 mm.
9 Heat shock
Clause 9 of IEC 6031 7-0-1 :201 3 applies. The minimum heat shock temperature shall be 1 55 °C.
1 0 Cut-through
No failure shall occur within 2 min at 1 70 °C.
1 1 Resistance to abrasion (nominal conductor diameters from 0,250 mm up to and including 2,000 mm)
The wire shall meet the requirements given in Table 1 .
For intermediate nominal conductor diameters, the value of the next larger nominal conductor diameter shall apply.
1 2 Resistance to solvents
Clause 1 2 of IEC 6031 7-0-1 :201 3 applies.
1 3 Breakdown voltage
Clause 1 3 of IEC 6031 7-0-1 :201 3 applies. The elevated temperature shall be 1 30 °C.
1 4 Continuity of insulation
Clause 1 4 of IEC 6031 7-0-1 :201 3 applies.
1 5 Temperature index
Clause 1 5 of IEC 6031 7-0-1 :201 3 applies. The minimum temperature index shall be 1 30.
1 6 Resistance to refrigerants
Test inappropriate.
1 7 Solderability
1 7.1 Nominal conductor diameters up to and including 0,1 00 mm
The temperature of the solder bath shall be (375 ± 5) °C. The maximum immersion time shall e 2 s.
The surface of the tinned wire shall be smooth and free from holes and enamel residues.
1 7.2 Nominal conductor diameter over 0,1 00 mm
The temperature of the solder bath shall be (375 ± 5) °C. The maximum immersion time (in seconds) shall be the following multiple of the nominal conductor diameter (in millimetres) with a minimum of 2 s. BS IEC 60317-4 pdf download.

Download infomation Go to download
Note: If you can share this website on your Facebook,Twitter or others,I will share more.
IEC 61300-2-40-2000 pdf free download – Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors IEC Standards

IEC 61300-2-40-2000 pdf free download – Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors

IEC 61300-2-40-2000 pdf free download - Fibre optic interconnecting devices and passive components – Basic test and measurement procedures – Part 2-40: Tests – Screen testing of attenuation of single- mode tuned angled optical connectors. 1.1Scope and...
Download Now

LEAVE A REPLY

Anonymous netizen Fill in information