ANSI SCTE 186-2016 pdf free download – Product Environmental Requirements for Cable Telecommunications

02-19-2022 comment

ANSI SCTE 186-2016 pdf free download – Product Environmental Requirements for Cable Telecommunications.
The specification purpose is to define product environmental and sustainability requirements
1) by referencing existing international standards;
2) by using requirements from cable operator specifications; and
3) by adding cable system specific requirements as needed. It is not the intent of this document to replace existing standards or cable operator requirements. This specification defines product physical, environmental, electrical, and sustainability requirements during transportation, storage, operation, and disposal. The specification is limited to indoor shelf, frame, rack, and cabinet level mission critical cable systems equipment. Facilities for which this specification generally applies are network data centers and cable headends.
This specification also applies to unmanned or remotely monitored distribution hubs where hub location, construction, and HVAC capabilities can result in less tightly controlled ambient operating climates and longer duration environmental stresses. The specification does not address requirements for outside cable plant equipment.
1.3. Benefits SCTE 186 provides cable operators a single reference point that defines energy savings and sustainability requirements for inside plant cable equipment. This standard provides cable operators means to implement and require more energy and environmentally friendly equipment. Cable operators should see financial operating energy savings as a result of implementing SCTE 186.
1.4. Intended Audience
Cable operator procurement and equipment engineering teams and inside plant equipment manufacturers will benefit from leveraging this standard.
1.5. Areas for Further
Investigation or to be Added in Future Versions None at time of 2016 update. 1.6. Target Equipment Example equipment includes CMTSs, receivers, modulators, video encoders, multimedia gateways, servers, routers, switches, network equipment, network storage units, edge routers, add-drop multiplexors and edge QAMs. Uninterruptable Power Supplies are not in scope for this document. 2. Normative References The following documents contain provisions, which, through reference in this text, constitute provisions of this document. At the time of Subcommittee approval, the editions indicated were valid. All documents are subject to revision; and while parties to any agreement based on this document are encouraged to investigate the possibility of applying the most recent editions of the documents listed below, they are reminded that newer editions of those documents might not be compatible with the referenced version.
2.1. SCTE References
• ANSI/SCTE 46-2007, Test Methods for AC to DC Power Supplies
• ANSI/SCTE 81-2012, Surge Withstand Test Procedure
• ANSI/SCTE 129-2007, Drop Passives, Bonding Blocks (Without Surge Protection)
• ANSI/SCTE 158-2009, Recommended Environmental Condition Ranges for Broadband Communications Equipment
• SCTE SMS 001-2011, Facilities Energy Managment and Recommended Practices 2011
2.2. Standards from Other Organizations
• ANSI T1.336-2009, Engineering Requirements for a Universal Telecom Framework
• ANSI/UL60950-1-2011, 2 nd Edition, 2011-12-19, Information Technology Equipment-Safety-Part 1, General Requirements
• ANSI Z136.1-2014, American National Standard for Safe Use of Lasers
• ANSI Z136.2-2012, American National Standard; Safe Use of Optical Fiber Communications Systems Utilizing Laser Diode and LED Sources
• ANSI C63.4-2014, American National Standard Methods for Measurement of Radio-Noise Emissions for Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
• ANSI T1.307-2007, Fire Resistance Criteria – Ignitability Requirements for Equipment Assemblies, Ancillary Non-Metallic Apparatus, and Fire Spread Requirements for Wire and Cable
• ANSI T1.319-2002, Equipment Assemblies – Fire Propagation Risk Assessment Criteria. 2002.
• ANSI T1.319-2002, Telecom Equipment Assemblies – Fire Propagation Risk Assessment Criteria
• ASHRAE-2015, Thermal Guidelines for Data Processing Environments, Fourth Edition. 2015.
• ASHRAE-2009, Design Considerations for Datacom Equipment Centers, Second Edition. ISBN 9781933742489, 2009
• ASHRAE-2009, Best Practices for Data Center Facility Energy Efficiency, 2 nd Edition, ISBN 978-1-933742-27-4, 2009
• ASHRAE Standard 52.1-1992, Gravimetric and Dust-Spot Procedures for Testing Air Cleaning Devices Used in General Ventilation for Removing Particulate Matter
• ASHRAE Standard 52.2 Addenda a, b and d-2015, Method of Testing General Ventilation Air Cleaning Devices for Removal Efficiency by Particle Size, 2015.ANSI SCTE 186 pdf download.