ANSI SCTE 156-2019 pdf free download – Specification for Mainline Plug (Male) to Cable Interface.
The primary purpose of this specification is to assure acceptable electrical, mechanical and environmentalperformance of the cable and connector interface. The scope of this standard will be directed to
acceptable performance of impedance,galvanic action, loop resistance, cable retention, intermodulationdistortion, signal response, RF shielding, and watertight seals. This specification in no way should limit orrestrict any manufacturers from innovative designs and product improvements.
1. This specification applies to the interface between ANSISCTE 92, Specification for 5/8 – 24 Plug(Male),Trunk and Distribution Connectors and 75-ohm coaxial aluminum hardline cable
manufactured to ANSI/SCTE 15 and ANSI/SCTE100.
2. 75-ohm coaxial cables and connectors are used to transport radio frequency (RF) signals and ACpower between active and passive equipment.
3. Unless otherwise specified, all requirements in this document shall meet the performancerequirements stated herein after thermal conditioning from -40 C to 60 ℃.
4. This document includes requirements for DOCSIS 3.1 operation.
2.Normative References
The following documents contain provisions,which, through reference in this text, constitute provisionsof the standard.At the time of Subcommittee approval, the editions indicated were valid. All standardsare subject to revision; and while parties to any agreement based on this standard are encouraged toinvestigate the possibility of applying the most recent editions of the documents listed below, they arereminded that newer editions of those documents may not be compatible with the referenced version.
2.1.SCTE References
.ANSISCTE 15 2006, Specification for Trunk, Feeder and Distribution Coaxial Cable.ANSI/SCTE 48-12015,Test Method for Measuring Shielding Effectiveness of Passive
and Actives Devices Using a GTEM Cell
ANSI/SCTE 60 2010, Test Method for Interface Moisture Migration Double Ended.ANSISCTE 92 2012,Specification for 5/8-24 Plug (Male), Trunk and Distribution
Connectors
ANSI/SCTE 93 2013, Test Method for Connector/Cable Twist
ANSI/SCTE 100 2010, Specification for 75 Ohm Smooth Aluminum Subscriber Access Cable
ANSI/SCTE 101 2011,“Mainline” Splice Connector Return Loss
ANSISCTE 102 2010, Cable Retention Force Testing of Trunk and DistributionConnectors
ANSI/SCTE 109 2010,Test Procedure for Common Path Distortion(CPD)
ANSI/SCTE 125 2011,“Mainline” Pin (Plug) Connector Return Loss
ANSI/SCTE 144 2012,Test Procedure for Measuring Transmission and Reflection
ANSI/SCTE 152 2014,Test Procedure for Contact Resistance Measurement of MainlinePlug Interface
2.2. Standards from other Organizations
• ASTM D 1171, Test Method for Rubber Deterioration
• ASTM G 154 – Standard Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials
3. Informative References
The following documents may provide valuable information to the reader but are not required when complying with this standard.
• No references are applicable
5. Center Conductor Interface
5.1. Mechanical The center conductor seizure device shall hold the following cable center conductor sizes to no less than the following retention forces when measured per ANSI/SCTE 102 Cable Retention Force Testing of Trunk and Distribution Connectors, and prepared to the lengths as shown in Figure 2.
5.2. Electrical The initial contact resistance reading shall not exceed 3 milliohms and may not exceed an additional 2 milliohms after being cycled from -40 °C to 60 °C, with 2 hour dwell times at each temperature extreme and 1 hour ramp times between temperature transitions, for a period of 7 days, as shown in Figure 1 and tested in accordance to ANSI/SCTE 152 Test Procedure for Contact Resistance Measurement of Mainline Plug Interface.
6. Outer Conductor Interface 6.1. Mechanical The cable sheath gripping mechanism shall be designed to hold the following cable outer conductor sizes to no less than the following retention forces when used with a support sleeve as described in Section 8 and when measured per ANSI/SCTE 102, Cable Retention Force Testing of Trunk and Distribution Connectors.ANSI SCTE 156 pdf download.
ANSI SCTE 156-2019 pdf free download – Specification for Mainline Plug (Male) to Cable Interface