ANSI SCTE 155-2017 pdf free download – Indoor “F” Female to “F” Female Inline Splice.
The purpose of this document is to recommend the mechanical and electrical standards for 75 ohm broadband radio frequency (RF) devices that provide an indoor inline connection between two type “F” male connectors that conform to ANSI/SCTE 123 2011, Specification for “F” Connector, Male, Feed- Through or ANSI/SCTE 124 2011, Specification for “F” Connector, Male, Pin Type. The mechanical configuration is designed to accommodate wall plate and bulkhead applications. This specification is not intended to restrict any manufacturer’s innovation and improvement. The specification may be amended in the future as deemed appropriate.
2. Normative References The following documents contain provisions, which, through reference in this text, constitute provisions of the standard. At the time of Subcommittee approval, the editions indicated were valid. All standards are subject to revision; and while parties to any agreement based on this standard are encouraged to investigate the possibility of applying the most recent editions of the documents listed below, they are reminded that newer editions of those documents may not be compatible with the referenced version.
• ANSI/SCTE 04 2014, Test Method for “F” Connector Return Loss
• ANSI/SCTE 48-1 2012, Test Method for Measuring Shielding Effectiveness of Passive and Active Devices Using a GTEM Cell
• ANSI/SCTE 103 2012, Test Method for DC Contact Resistance, Drop cable to F-Connectors and F81 Barrels
• ANSI/SCTE 123 2011; Specification for “F” Connector, Male, Feed-Through
• ANSI/SCTE 124 2011; Specification for “F” Connector, Male, Pin Type
• ANSI/SCTE 143 2013, Test Method for Salt Spray
• ANSI/SCTE 144 2012, Test Procedure for Measuring Transmission and Reflection
4. Mechanical
4.1. Dimensions The physical dimension of the inline splice shall meet the dimensional requirements of Figure 1.
4.2. Center Conductor Mating The center conductor contact of both ends shall accept male “F” connector center conductors whose diameters are between 0.0250” (0.64 mm) diameter and 0.0403” (1.02 mm) diameter. The junction shall have a minimum retention force of 50 grams with a 0.0320” (0.81 mm) diameter conductor inserted after the contact is mated 25 times with a center conductor whose diameter is 0.0403” (1.02 mm) when tested in accordance to IPS TP 417, Test Method for F Connector Center Conductor Retention.
5. Electrical
5.1. Bandwidth Bandwidth shall be a minimum of 5 MHz to 1,218 MHz. Unless otherwise specified, all performance parameters listed shall be tested in this frequency range.
5.2. Insertion Loss Shall not exceed 0.1 dB for frequencies between 5 MHz and 600 MHz, 0.2 dB, for frequencies above 600 MHz and up to 1,002 MHz, 0.25 dB for frequencies above 1002 MHz and up to 1,218 MHz and 0.30 dB for frequencies above 1218 MHz and up to 1794 MHz when tested in accordance to ANSI/SCTE 144 2012, Test Procedure for Measuring Transmission and Reflection.
5.3. Return Loss
Shall be no worse than 30 dB, when tested in accordance to ANSISCTE 042014,Test Method for “FConnector Return Loss.
5.4. Shielding Effectiveness
The shielding effectiveness of the assembled components shall be a minimum of 100dB, when tested inaccordance with ANSI/SCTE48-1 2012,Test Method for Measuring Shielding Effectiveness of Passiveand Active Devices Using a GTEM Cell.
5.5. Center Conductor Contact Resistance
The center conductor junction of the female “F”port to male F center conductor shall have a DC contactresistance of less than 25 milliohms after the testing performed in IPS TP417 and then tested in
accordance to ANSI/SCTE 103 2012.
5.6. Outer Conductor Contact Resistance
The outer conductor junction of the indoor female “F”port to male F connector shall have a DC contactresistance less than 10 milliohms when tightened to 40 1b.-in. and tested to ANSISCTE 103 2012.
6. Environmental
6.1. Salt Spray
Components shall meet the electrical performance as outlined in section 5, after 1000 Hours of the saltspray when tested in accordance to ANSI/SCTE 143 2013.
6.2. Temperature
Components shall meet all performance requirements during and after exposure to temperatures rangingfrom -40°F(-40°C) to +140°F(+60°C) inclusive.ANSI SCTE 155 pdf download
ANSI SCTE 155-2017 pdf free download – Indoor “F” Female to “F” Female Inline Splice
Note:
If you can share this website on your Facebook,Twitter or others,I will share more.